other

800G QSFP-DD SR8 850nm 100m MPO-16 APC


Features
  • QSFP-DD Serial Optical Interface
8x100G PAM4 retimed 800GAUI-8 electrical interface
MPO-16 APC connector
8 channel VCSEL arrays and 8 channels PIN photo detector arrays
Maximum link length of 60m on OM3 or 100m on OM4
  • QSFP-DD MSA Compliant
Hot Pluggable QSFP-DD form factor
Compliant to QSFP-DD-Hardware-Rev 6.3 MSA
Compliant to CMIS 5.2
  • Support Protocol
Compliant to IEEE 802.3db
Compliant to IEEE 802.3ck
  • Low Power Consumption
Less than 14W in temperature range of 0 to 70℃



  • 产品详细信息


800G QSFP-DD SR8 850nm 100m MPO-16 APC

RQDD-800G-SR8

 


Applications

  • 800GBASE-SR8 800G Ethernet
  • Data center




1.General Description


RQDD-800G-SR8 is a Eight-Channel, Parallel, Pluggable, Fiber-Optic QSFP-DD for 800Gigabit Ethernet applications. This transceiver is a high performance module for short-reach data communication and interconnect application. It integrates eight data lanes in each direction with 8x53.125GBd. The transmission distance of QSFP-DD SR8 is up to 60 meters over OM3 MMF or 100 meters over OM4 MMF. This module is designed to operate over multimode fiber systems using a nominal wavelength of 850nm.


2. Absolute Maximum Ratings and Recommended Operating Conditions


Table 2.1 Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Storage Temperature

Ts

-40

85

°C

Case Operating Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Supply Voltage

Vcc

-0.5

3.6

V

Receiver Damage Threshold, per Lane

PRdmg

5


dBm


Table 2.2 Recommended Operating Conditions

Parameter

Symbol

Min

Max

Unit

Operating Case Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Power Supply Voltage

Vcc

3.135

3.465

V

Total Power Consumption1

Pc

-

14

W

Supply Current



4.46

A

Bit Rate

BR


850

Gbps

Fiber Length on OM3 MMF



60

m

Fiber Length on OM4 MMF



100

m

I2C Clock Frequency

0


400

kHz


Notes:

1.Under condition of 3.465V operating supply voltage, and 70℃ case temperature.




3. Optical Specification

3.1  Optical Transmitter


Table 3.1 Transmitter Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit


Data rate per lane

DR


53.125


GBd


Modulation format


PAM4


Center Wavelength 1

λ

840

860

868

nm

RMS spectral width

σ



0.6

nm

Average Launch power, each lane

Pavg

-4.6


4

dBm

Optical Power OMA, each Lane,max

POMA

3.5

dBm

OMAouter, each lane min

max (TECQ, TDECQ) <1.8 dB

max [-2.6 , max(TECQ,TECQ) – 4.4]

dBm

1.8 < max (TECQ, TDECQ) < 4.4 dB

Transmitter and dispersion eye closure (TDECQ), each lane

TDECQ



4.4

dB

Transmitter eye closure for PAM4 (TECQ), each lane

TECQ



4.4

dB

Extinction ratio

ER

2.5



dB

Transmitter power excursion, each lane




2.3

dBm

Optical Return Loss Tolerance

ORLT



14

dB

Optical Power for TX DISABLE




-30

dBm

Encircled fluxb2


≥86% at 19 um

≤30% at 4.5 um



Notes:

1. Defined according to the performance of the laser used.

2. Measured into type A1a.2 or type A1a.3, or A1a.4, 50 um fiber, in accordance with IEC 61280-1-4.



3.2  Optical Receiver


Table 3.2 Receiver Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit

Data rate per lane

BR


53.125


GBd

Modulation format


PAM4


Center Wavelength

λ

842

850

948

nm

Damage threshold


5



dBm

Average receive power, each lane


–6.4


4

dBm

Receive power, each lane (OMAouter)




3.5

dBm

Receiver reflectance

Rr



–15

dB

Receiver sensitivity, each lane1


RS = max (-4.6 , TECQ – 6.4)

dBm

Stressed receiver sensitivity, each lane




–2

dBm

Rx LOS

Assert


-15



dBm

De-assert




-7.5

dBm

Hysteresis


0.5


5

dB


Notes:

1. Receiver sensitivity is informative and is defined for a transmitter with a value of TECQ.  Measured with conformance test signal at TP3 for BER = 2.4E-4 Pre-FEC.



4.Electrical Specification


Table 4.1 Electrical Specifications

Parameters

Min

Typical

Max

Unit

Pre FEC Bit Error Ratio



2.4E-4


Post FEC Bit Error Ratio



1E-12


Transmitter (each Lane)

Differential pk-pk Input Voltage tolerance

750



mV

Differential Termination Mismatch



10

%

Eye height

10



mV

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)

dB

Vertical eye closure



12

dB

Effective return loss

7.3



dB

Transition Time

10



ps

Receiver (each Lane)

Differential data output swing

300


900

mVpp

Differential termination mismatch



10

%

Eye height

15



mV

Vertical eye closure



12

dB

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)


Effective return loss

8.5



dB

Transition time

8.5



ps



5. Ordering Information

Part Number

Temperature

Range

Distance

Fiber Type

E/O

O/E

RQDD-800G-SR8

0 to 70℃

100m

MMF

VCSEL

850nm

PIN




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G OSFP DR8 SM MPO12 Optical Transceiver IB 800G OSFP DR8 SM MPO12 Optical Transceiver IB
Features Form Factor: Hot-pluggable OSFP800 form factor Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1 Management Interface: I2C management interface Reach: Up to 500m over MPO/APC single mode fiber Power consumption: 16 W max Operating case temperature: 0 ~ 70 ℃ Power Supply: Single 3.3V power supply Compliance Form Factor: OSFP MSA Rev 5.0 Optical: IEEE802.3cd /IEEE802.3bs Electrical: IEEE802.3ck Firmware: CMIS 5.2 Environment: RoHS Stability: GR-468-CORE Applications 800Gb/s Ethernet Data Center
200G QSFP56 AOC cable 200G QSFP56 AOC Transceiverr
Features Up to 50Gbps data rate per channel by PAM4 modulation Support 200GAUI-4 electrical interface Integrated 850nm VCSEL array and PD array Single +3.3V power supply Case temperature range: 0 ~ +70℃ Hot-pluggable QSFP form factor RoHS complaint Applications Data centers and Cloud Networks Standards IEEE 802.3cd SFF 8679 CMIS4.0 or SFF8636
网管平台(NMU) 网管平台(NMU)
支持热插拔,失效后不影响业务板卡的正常工作。 支持本地、远程在线升级同时不影响业务板卡的正常工作。 支持基于SNMP统一网管平台,网管方式CLI、Web、NetView(图形化界面)。 支持带内、带外级联网管及提供3个SFP光口、2个RJ45电口和1个Console串口。 提供强大的多层次网络拓扑管理功能,实现网络拓扑快速自动发现并生成直观生动的显示图形。 遵循TMN规范,实现了设备管理、监视与部署、软件升级管理、配置文件管理、告警和性能管理等功能,实现从设备级到网络级全方位的网络管理。
保偏滤波器 980 1064nm保偏滤波器
Low insertion loss High Extinction Ratio High channel isolation High stability and reliability
DWDM R B filter DWDM 红蓝光 滤波器件
DWDM R B Filter, DWDM C-Band. Low insertion loss High channel isolation Low polarization dependent loss Exceptional reliability and stability
100G QSFP28 DWDM 100Gb/s QSFP28 DWDM Dual CS Adaptor Transceiver
100G QSFP28 DWDM optical transceiver module, support 48*100Gb/s DWDM System and up to 80 km transmission on SM fiber, it works in high-speed IDC connection solutions.
空闲光纤管理系统:智能优化,高效管理,释放光纤潜力 空闲光纤管理系统:智能优化,高效管理,释放光纤潜力
特点: 1U机箱可接入48芯,24路双芯业务, 业务和检测同时接入,互不影响 设备断电(或故障)也不影响业务正常通信 实时监控与状态分析 - 光纤状态监测:实时监测光纤链路线损状态。 - 故障预警:自动识别光纤链路中的潜在问题,并及时发出警报,帮助维护人员快速响应。
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系