800G QSFP-DD SR8 850nm 100m MPO-16 APC


Features
  • QSFP-DD Serial Optical Interface
8x100G PAM4 retimed 800GAUI-8 electrical interface
MPO-16 APC connector
8 channel VCSEL arrays and 8 channels PIN photo detector arrays
Maximum link length of 60m on OM3 or 100m on OM4
  • QSFP-DD MSA Compliant
Hot Pluggable QSFP-DD form factor
Compliant to QSFP-DD-Hardware-Rev 6.3 MSA
Compliant to CMIS 5.2
  • Support Protocol
Compliant to IEEE 802.3db
Compliant to IEEE 802.3ck
  • Low Power Consumption
Less than 14W in temperature range of 0 to 70℃



  • 产品详细信息


800G QSFP-DD SR8 850nm 100m MPO-16 APC

RQDD-800G-SR8

 


Applications

  • 800GBASE-SR8 800G Ethernet
  • Data center




1.General Description


RQDD-800G-SR8 is a Eight-Channel, Parallel, Pluggable, Fiber-Optic QSFP-DD for 800Gigabit Ethernet applications. This transceiver is a high performance module for short-reach data communication and interconnect application. It integrates eight data lanes in each direction with 8x53.125GBd. The transmission distance of QSFP-DD SR8 is up to 60 meters over OM3 MMF or 100 meters over OM4 MMF. This module is designed to operate over multimode fiber systems using a nominal wavelength of 850nm.


2. Absolute Maximum Ratings and Recommended Operating Conditions


Table 2.1 Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Storage Temperature

Ts

-40

85

°C

Case Operating Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Supply Voltage

Vcc

-0.5

3.6

V

Receiver Damage Threshold, per Lane

PRdmg

5


dBm


Table 2.2 Recommended Operating Conditions

Parameter

Symbol

Min

Max

Unit

Operating Case Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Power Supply Voltage

Vcc

3.135

3.465

V

Total Power Consumption1

Pc

-

14

W

Supply Current



4.46

A

Bit Rate

BR


850

Gbps

Fiber Length on OM3 MMF



60

m

Fiber Length on OM4 MMF



100

m

I2C Clock Frequency

0


400

kHz


Notes:

1.Under condition of 3.465V operating supply voltage, and 70℃ case temperature.




3. Optical Specification

3.1  Optical Transmitter


Table 3.1 Transmitter Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit


Data rate per lane

DR


53.125


GBd


Modulation format


PAM4


Center Wavelength 1

λ

840

860

868

nm

RMS spectral width

σ



0.6

nm

Average Launch power, each lane

Pavg

-4.6


4

dBm

Optical Power OMA, each Lane,max

POMA

3.5

dBm

OMAouter, each lane min

max (TECQ, TDECQ) <1.8 dB

max [-2.6 , max(TECQ,TECQ) – 4.4]

dBm

1.8 < max (TECQ, TDECQ) < 4.4 dB

Transmitter and dispersion eye closure (TDECQ), each lane

TDECQ



4.4

dB

Transmitter eye closure for PAM4 (TECQ), each lane

TECQ



4.4

dB

Extinction ratio

ER

2.5



dB

Transmitter power excursion, each lane




2.3

dBm

Optical Return Loss Tolerance

ORLT



14

dB

Optical Power for TX DISABLE




-30

dBm

Encircled fluxb2


≥86% at 19 um

≤30% at 4.5 um



Notes:

1. Defined according to the performance of the laser used.

2. Measured into type A1a.2 or type A1a.3, or A1a.4, 50 um fiber, in accordance with IEC 61280-1-4.



3.2  Optical Receiver


Table 3.2 Receiver Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit

Data rate per lane

BR


53.125


GBd

Modulation format


PAM4


Center Wavelength

λ

842

850

948

nm

Damage threshold


5



dBm

Average receive power, each lane


–6.4


4

dBm

Receive power, each lane (OMAouter)




3.5

dBm

Receiver reflectance

Rr



–15

dB

Receiver sensitivity, each lane1


RS = max (-4.6 , TECQ – 6.4)

dBm

Stressed receiver sensitivity, each lane




–2

dBm

Rx LOS

Assert


-15



dBm

De-assert




-7.5

dBm

Hysteresis


0.5


5

dB


Notes:

1. Receiver sensitivity is informative and is defined for a transmitter with a value of TECQ.  Measured with conformance test signal at TP3 for BER = 2.4E-4 Pre-FEC.



4.Electrical Specification


Table 4.1 Electrical Specifications

Parameters

Min

Typical

Max

Unit

Pre FEC Bit Error Ratio



2.4E-4


Post FEC Bit Error Ratio



1E-12


Transmitter (each Lane)

Differential pk-pk Input Voltage tolerance

750



mV

Differential Termination Mismatch



10

%

Eye height

10



mV

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)

dB

Vertical eye closure



12

dB

Effective return loss

7.3



dB

Transition Time

10



ps

Receiver (each Lane)

Differential data output swing

300


900

mVpp

Differential termination mismatch



10

%

Eye height

15



mV

Vertical eye closure



12

dB

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)


Effective return loss

8.5



dB

Transition time

8.5



ps



5. Ordering Information

Part Number

Temperature

Range

Distance

Fiber Type

E/O

O/E

RQDD-800G-SR8

0 to 70℃

100m

MMF

VCSEL

850nm

PIN




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G OSFP DR8 SM MPO12 Optical Transceiver IB 800G OSFP DR8 SM MPO12 Optical Transceiver IB
Features Form Factor: Hot-pluggable OSFP800 form factor Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1 Management Interface: I2C management interface Reach: Up to 500m over MPO/APC single mode fiber Power consumption: 16 W max Operating case temperature: 0 ~ 70 ℃ Power Supply: Single 3.3V power supply Compliance Form Factor: OSFP MSA Rev 5.0 Optical: IEEE802.3cd /IEEE802.3bs Electrical: IEEE802.3ck Firmware: CMIS 5.2 Environment: RoHS Stability: GR-468-CORE Applications 800Gb/s Ethernet Data Center
400G QSFP28 DR4 400G QSFP-DD DR4 PAM4 1310nm 500M MPO Optical Transceiver
400G QSFP-DD DR4 optical transceiver module, support 400Gb/s and up to 500m transmission on SM fiber, it works in high-speed IDC connection solutions.
2X2磁光开关 2X2磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
100G QSFP28 DWDM 40GBASE-SR Bi-Directional QSFP+ 850/900nm 100m DOM LC MMF Optical Transceiver Module
40G QSFP+ BIDI optical transceiver module is a pluggable optical transceiver with a duplex LC connector interface for short-reach data communication and interconnect applications using Multi-Mode Fiber (MMF). It offers customers a compelling solution that enables reuse of their existing 10 Gb duplex MMF infrastructure for migration to 40 Gigabit Ethernet connectivity.
100G QSFP28 to 2x 50G QSFP28 AOC cable 100G QSFP28 to 2x 50G QSFP28 AOC Transceiver
Features 4 channels full-duplex transceiver modules Transmission data rate up to 28Gbps per channel Support 40GE and 56G FDR data rate 4 channels 850nm VCSEL array 4 channels PIN photo detector array Internal CDR circuits on both receiver and transmitter channels Support CDR bypass Low power consumption: QSFP28- 100G < 2.5W and QSFP28-50G
10G 1310nm 10km,工业级小型化光模块 10G 1310nm 10KM 双纤 工业级 10PIN 表贴 全国产化 小型化光模块
特性描述 更紧凑的结构设计——模块高度仅12mm 适应于高速信号完整性的表贴I/O引脚 全金属外壳 军品级温度范围,采用抗振动设计 具备接收数据信号检测功能 仅使用+3.3 V单电源 LC接口形式 引脚及安装尺寸全面兼容STRATOS产品
100G QSFP28 LR4 100G QSFP28 LR4 1310nm 10km LC Optical Transceiver
100G QSFP28 LR4 optical transceiver module, support 100Gb/s and up to 10 km transmission on SM fiber, it works in high-speed IDC connection solutions, and so on. Features 4 lanes MUX/DEMUX design Integrated LAN WDM TOSA / ROSA for up to 10 km reach over SMF Support 100GBASE-ER4 for line rate of 103.125Gbps and OTU4 for line rate of 111.81Gbps Aggregate bandwidth of >100Gbps Duplex LC connectors Compliant with IEEE 802.3-2012 Clause 88 standard IEEE 802.3bm CAUI-4 chip to module electrical standard ITU-T G.959.1-2012-02 standard· Single +3.3V power supply operating Built-in digital diagnostic functions Temperature range 0°C to 70°C RoHS Compliant Part Support FEC(Forward Error Correction)
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系