800G QSFP-DD SR8 850nm 100m MPO-16 APC


Features
  • QSFP-DD Serial Optical Interface
8x100G PAM4 retimed 800GAUI-8 electrical interface
MPO-16 APC connector
8 channel VCSEL arrays and 8 channels PIN photo detector arrays
Maximum link length of 60m on OM3 or 100m on OM4
  • QSFP-DD MSA Compliant
Hot Pluggable QSFP-DD form factor
Compliant to QSFP-DD-Hardware-Rev 6.3 MSA
Compliant to CMIS 5.2
  • Support Protocol
Compliant to IEEE 802.3db
Compliant to IEEE 802.3ck
  • Low Power Consumption
Less than 14W in temperature range of 0 to 70℃



  • 产品详细信息


800G QSFP-DD SR8 850nm 100m MPO-16 APC

RQDD-800G-SR8

 


Applications

  • 800GBASE-SR8 800G Ethernet
  • Data center




1.General Description


RQDD-800G-SR8 is a Eight-Channel, Parallel, Pluggable, Fiber-Optic QSFP-DD for 800Gigabit Ethernet applications. This transceiver is a high performance module for short-reach data communication and interconnect application. It integrates eight data lanes in each direction with 8x53.125GBd. The transmission distance of QSFP-DD SR8 is up to 60 meters over OM3 MMF or 100 meters over OM4 MMF. This module is designed to operate over multimode fiber systems using a nominal wavelength of 850nm.


2. Absolute Maximum Ratings and Recommended Operating Conditions


Table 2.1 Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Storage Temperature

Ts

-40

85

°C

Case Operating Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Supply Voltage

Vcc

-0.5

3.6

V

Receiver Damage Threshold, per Lane

PRdmg

5


dBm


Table 2.2 Recommended Operating Conditions

Parameter

Symbol

Min

Max

Unit

Operating Case Temperature

Top

0

70

°C

Relative Humidity (non-condensation)

RH

15

85

%

Power Supply Voltage

Vcc

3.135

3.465

V

Total Power Consumption1

Pc

-

14

W

Supply Current



4.46

A

Bit Rate

BR


850

Gbps

Fiber Length on OM3 MMF



60

m

Fiber Length on OM4 MMF



100

m

I2C Clock Frequency

0


400

kHz


Notes:

1.Under condition of 3.465V operating supply voltage, and 70℃ case temperature.




3. Optical Specification

3.1  Optical Transmitter


Table 3.1 Transmitter Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit


Data rate per lane

DR


53.125


GBd


Modulation format


PAM4


Center Wavelength 1

λ

840

860

868

nm

RMS spectral width

σ



0.6

nm

Average Launch power, each lane

Pavg

-4.6


4

dBm

Optical Power OMA, each Lane,max

POMA

3.5

dBm

OMAouter, each lane min

max (TECQ, TDECQ) <1.8 dB

max [-2.6 , max(TECQ,TECQ) – 4.4]

dBm

1.8 < max (TECQ, TDECQ) < 4.4 dB

Transmitter and dispersion eye closure (TDECQ), each lane

TDECQ



4.4

dB

Transmitter eye closure for PAM4 (TECQ), each lane

TECQ



4.4

dB

Extinction ratio

ER

2.5



dB

Transmitter power excursion, each lane




2.3

dBm

Optical Return Loss Tolerance

ORLT



14

dB

Optical Power for TX DISABLE




-30

dBm

Encircled fluxb2


≥86% at 19 um

≤30% at 4.5 um



Notes:

1. Defined according to the performance of the laser used.

2. Measured into type A1a.2 or type A1a.3, or A1a.4, 50 um fiber, in accordance with IEC 61280-1-4.



3.2  Optical Receiver


Table 3.2 Receiver Optical Interface

Parameter

Symbol

Min

Typical

Max

Unit

Data rate per lane

BR


53.125


GBd

Modulation format


PAM4


Center Wavelength

λ

842

850

948

nm

Damage threshold


5



dBm

Average receive power, each lane


–6.4


4

dBm

Receive power, each lane (OMAouter)




3.5

dBm

Receiver reflectance

Rr



–15

dB

Receiver sensitivity, each lane1


RS = max (-4.6 , TECQ – 6.4)

dBm

Stressed receiver sensitivity, each lane




–2

dBm

Rx LOS

Assert


-15



dBm

De-assert




-7.5

dBm

Hysteresis


0.5


5

dB


Notes:

1. Receiver sensitivity is informative and is defined for a transmitter with a value of TECQ.  Measured with conformance test signal at TP3 for BER = 2.4E-4 Pre-FEC.



4.Electrical Specification


Table 4.1 Electrical Specifications

Parameters

Min

Typical

Max

Unit

Pre FEC Bit Error Ratio



2.4E-4


Post FEC Bit Error Ratio



1E-12


Transmitter (each Lane)

Differential pk-pk Input Voltage tolerance

750



mV

Differential Termination Mismatch



10

%

Eye height

10



mV

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)

dB

Vertical eye closure



12

dB

Effective return loss

7.3



dB

Transition Time

10



ps

Receiver (each Lane)

Differential data output swing

300


900

mVpp

Differential termination mismatch



10

%

Eye height

15



mV

Vertical eye closure



12

dB

Common-mode to differential-mode return loss

IEEE802.3ck Equation (120G–1)


Effective return loss

8.5



dB

Transition time

8.5



ps



5. Ordering Information

Part Number

Temperature

Range

Distance

Fiber Type

E/O

O/E

RQDD-800G-SR8

0 to 70℃

100m

MMF

VCSEL

850nm

PIN




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G OSFP DR8 SM MPO12 Optical Transceiver IB 800G OSFP DR8 SM MPO12 Optical Transceiver IB
Features Form Factor: Hot-pluggable OSFP800 form factor Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1 Management Interface: I2C management interface Reach: Up to 500m over MPO/APC single mode fiber Power consumption: 16 W max Operating case temperature: 0 ~ 70 ℃ Power Supply: Single 3.3V power supply Compliance Form Factor: OSFP MSA Rev 5.0 Optical: IEEE802.3cd /IEEE802.3bs Electrical: IEEE802.3ck Firmware: CMIS 5.2 Environment: RoHS Stability: GR-468-CORE Applications 800Gb/s Ethernet Data Center
Mechanical Fiber Optical Switch 1x4 机械式光开关器件
Unmatched Low Cost, 1x4 Mechanical Optical Switch Low Optical Distortions High Isolation High Reliability Epoxy-Free Optical Path
工业级交换机 2光8电POE千兆工业级交换机 FW308GPS-2F
8*10/100/1000M自适应RJ45端口+2*千兆SFP端口(上行) FW308GPS-2F是一款工业全千兆管理型POE交换机,提供8个千兆POE端口,2个千兆光口,EMC工业4级的防护性能;波纹式高强度铝型材外壳、IP40等级、低功耗设计、抗震的导轨安装,-40℃-75℃的工作温度,可工作于恶劣环境。
保偏DWDM 无源保偏DWDM器件
Low insertion loss High Extinction Ratio High channel isolation High stability and reliability
48 X 10G 网络分流器 网络流量复制器 汇聚分流 TAP交换机 48 X 10G 网络分流器 网络流量复制器 汇聚分流 TAP交换机
19英寸标准机架式,1RU高度 48个10GE/GE接口(SFP+) 1个RJ45管理网口,1个RJ45串口 双路冗余电源 支持标准五元组、输入接口、VLAN ID、固定位置特征码过滤 支持VLAN、MPLS标签识别剥离 支持2层VLAN、4层MPLS标签、GRE/GTP/L2TP/PPTP/PPPOE等隧道报文(匹配时选择内层或者外层) 支持按GTP-U内层或外层IP分流和过滤匹配,分流模式内外层可配 规则容量 480条 支持CLI、SNMP、WEB管理、WEB管理支持HTTPS
100G CFP Module 100G CFP2 LR4 Dual Rate 10km Module
Features Supports multi-rate (100GE and OTU4); from 103.1Gb/s to 111.8Gb/s aggregate; Up to 10km transmission on SMF; LANWDM laser and PIN receiver with SOA; High speed I/O electrical interface (CAUI-4); MDIO interface with integrated Digital Diagnostic CFP2 MSA package with duplex LC connector; Single +3.3V power supply; Maximum power consumption 12W; Operating case temperature: 0 to +70 °C; Complies with IEEE802.3ba and ITU-T G.959.1; Complies with EU Directive 2015/863/EU; Application 100GBASE-LR4
Dual Fiber 18CH 1270nm-1610nm CWDM MUX DEMUX 18路 双纤双向 CWDM 带监控口 波分复用设备
CWDM MUX DEMUX, Multiplexing up to 18 Channels on Fiber Pair 1% Monitor Port for Signal Analyzing or Troubleshooting Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系